Ingress protection | IP54 |
---|---|
Power supply | 6x LR6 battery |
Operating temperature | -20…+50°C |
Storage temperature | -40…+70°C |
Humidity | 95% |
Mode | Distance along conductor |
---|---|
Power Mode | length of conductor |
Radio Mode | length of conductor |
Conductive Rod Mode | ength of unwound rod |
Mode | Range |
---|---|
Power Mode | to 3 m / 10 ft |
Radio Mode | to 2 m / 7 ft |
Transmitter Mode | to 3 m / 10 ft |
Accuracy |
---|
10% of depth in line or Sonde |
0.3 m to 3.0 m (1 ft to 10 ft) depth range |
Mode | Frequency |
---|---|
Power Mode | 50 Hz or 60 Hz |
Radio Mode | 15 kHz to 60 kHz |
8 kHz Mode | 8.192 (8 kHz) |
33 kHz mode | 32.768 (33 kHz) |
Auto mode | Power mode and Radio mode |
- 48 segment bar graph
- 5 mode indicators
- Battery status indicator
- Line depth indicator
- Sonde depth indicator
- Bluetooth indicator
- Integrated backlight
- Annual service indicator
- 3 alpha numeric dot matrix displays 5 x 7
2 membrane push buttons
Dual speakers:
- Audio volumes: 85 dBA @ 30 cm
- Tone: Power, Radio and Auto mode: continuous tone (different pitch for each tone),8 kHz and 33 kHz mode: pulsed tone (different pitch for each tone). All five tones aredifferent.
- pneumatic headphone sockets are integrated
- Type: 6 x LR6 (AA) alkaline
- Typical operating time: 40 hrs intermittent use at 20°C / 68°F; in 8 kHz mode or 33 kHz mode
- dimensions: 760 mm x 250 mm x 85 mm; 30 Inches x 10 Inches x 3.4 Inches
- weight: 2.7 kg / 6 lbs (including batteries)
Type | Description |
---|---|
Temperature operating | -20°C to +50°C -4°F to +122°F |
Temperature storage | -40°C to +70°C -40°F to +158°F |
Protection against Water, Dust and Sand | P54 (IEC 60529) Dust-protected |
Humidity | 95% RH non condensing. The effects of condensation are to be effectively counteracted by periodically drying out the product. |
- FCC Part 15 (applicable in US)
- Hereby, Sonel S.A. declares that the Locator LKO-1000 is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. Class 1 equipment according European Directive 1999/5/EC (R&TTE) can be placed on the market and be put into service without restrictions in any EEA member state.
- The conformity for countries with other national regulations not covered by the FCC part 15 or European directive 1999/5/EC has to be approved prior to use and operation.
50 Hz to 60 kHz
Receive only
Parameter | Value |
---|---|
Net weight (kg) | 2.6 |
Package weight (kg) | 4.7 |
Package width (cm) | 77.5 |
Package height (cm) | 43 |
Package length (cm) | 77.5 |