MPI-507 | KT-256F | |
---|---|---|
Safety and work conditions | ||
Measuring category according to EN 61010 | IV 300 V, III 600 V | - |
Ingress protection | IP67 | IP54 |
Dimensions | 220 x 102 x 61 mm | 194 x 62 x 76 mm |
Weight | ca. 0.8 kg | ca. 0,4 kg |
Memory and communication | ||
Memory of measurement results | 990 cells, 10 000 records | 32 GB |
Data transmission | Bluetooth | USB |
None | None |
A set of measuring instruments with accessories. The set includes:
- multifunctional electrical installations meter Sonel MPI-507,
- thermal imager Sonel KT-256F.
Capabilities
- MPI-507 | Measurement of short circuit loop parameters.
- MPI-507 | Testing RCD breakers of AC, A types.
- MPI-507 | Earth resistance measurement.
- MPI-507 | Insulation resistance measurement.
- MPI-507 | Measurement of resistance of protective conductors and equipotential bondings.
- MPI-507 | Phase sequence indication.
- KT-256 | Infrared diagnostics.
MPI-507
Multifunctional electrical installations meter
Measurement of short circuit loop parameters
- Measurement of short circuit loop impedance in networks with rated voltage: 220/380 V, 230 V/400 V, 240/415 V and frequency 45…65 Hz, operating voltage range: 180…460 V
- Indication of short circuit loop resistance R and short circuit loop reactance X
- Measurements of short circuit loop impedance with 15 mA current, without tripping the RCD circuit breaker
- Maximum test current: 7.6 A (at 230 V), 13.3 A (at 400 V)
Testing RCD breakers of AC, A types
- Testing of prompt, short-delay and selective RCDs with rated current values 10, 15, 30, 100, 300, 500 mA
- Measurement of IA trip current and tripping time tA for currents 0.5 IΔn, 1 IΔn, 2 IΔn, 5 IΔn
- RE and UB measurement without RCD tripping
- Extended AUTO function of RCD measurement, with the possibility of measuring ZL-PE with low current
- Measurement of IA and tA during one RCD tripping
Earth resistance measurement
- Measurement with 3-pole method.
Insulation resistance measurement
- Test voltage 100 V, 250 V, 500 V.
Measurement of resistance of protective conductors and equipotential bondings
- Measurement of protective connections continuity with a ±200 mA current in accordance with EN 61557-4
- Autocalibration of test leads - any leads can be used
- Low current resistance measurement with sound signaling
Phase sequence indication
KT-256F
Thermal imager
Features
- Measuring range: -20°C...550°C (-4°F... 1022°F).
- Quick start.
- Fast temperature measurement.
- Automatic signalling of exceeded alarm threshold.
- Autofocus.
- Saving IR images to SD card.
- Built-in Li-Ion battery with 16-hour working time.
- Interfaces: USB type C, SD slot.
- Can be set up on a tripod.
Parameter | Value |
---|---|
Net weight (kg) | 1 |
Package weight (kg) | 5.1 |
Package width (cm) | 13.5 |
Package height (cm) | 35 |
Package length (cm) | 42.5 |
Newsletter